How to calculate voltage regulation of distribution line

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../how-to- calculate-voltage-regulation-of-distribution-line

Jun 10, 2013 ... Voltage (load) regulation is to maintain a fixed voltage under different load. Voltage regulation is limiting factor to decide the size of conductor.

Electrical Thumb Rules You MUST Follow (Part 7)

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../electrical- thumb-rules-you-must-follow-part-7

Dec 23, 2013 ... 8 electrical thumb rules to follow: overhead conductor (cable size), transmission and distribution line (span, height of tower), types of towers.

An example of calculating the technical losses of T&D lines

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../an-example- of-calculating-the-technical-losses-of-td-lines

Apr 25, 2014 ... Transmission (technical) losses are directly effected on electrical tariff, but commercial ... EEP - Electrical Engineering Portal ... Technical losses of the distribution line mostly depend upon electrical load, type and size of conductor, length of line etc. ... He is member of Institution of Engineers (MIE), India.

Total Losses in Power Distribution and Transmission Lines | EEP

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../total-losses-in -power-distribution-and-transmission-lines-1

Aug 19, 2013 ... EEP - Electrical Engineering Portal ... It is fact that the unit of electric energy generated by Power Station does ... The conductor size of these feeders should be adequate. .... He is member of Institution of Engineers (MIE), India.

Electrical Thumb Rules You MUST Follow (Part 4)

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../electrical- thumb-rules-you-must-follow-part-4

MCB/MCCB/ELCB Termination Wire / Cable. Up to 20A MCB, Max. 25 Sq.

Defining Size and Location of Capacitor in Electrical System (2)

feedproxy.google.com/.../ElectricalEngineeringPortal/.../defining-size-and- location-of-capacitor-in-electrical-system-2

Mar 11, 2013 ... Deifinitions of size of circuit breaker, fuse and conductor of capacitor bank for transformer no-load compensation and motor compensation.

Electrical Thumb Rules You MUST Follow (Part 2)

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../electrical- thumb-rules-you-must-follow-part-2

Aug 28, 2013 ... Useful electrical equations: Load Factor = Average Power / Peak Power, Demand Factor, Sinusoidal Current: Form Factor, Cable Voltage Drop etc. ... EEP - Electrical Engineering Portal ... Size of Lightning Arrestor = 1.5x Phase to Earth Voltage or 1.5 x ... He is member of Institution of Engineers (MIE), India.

Analysing the costs of High Voltage Direct Current (HVDC ...

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../analysing-the- costs-of-high-voltage-direct-current-hvdc-transmission

Aug 6, 2014 ... EEP - Electrical Engineering Portal ... In a HVDC system, electric power is taken from a three-phase AC network system ... For a given cable conductor area, the line losses with HVDC cables is about 50% of that AC cables.

Electrical Safety Standards for LV/MV/HV (Part-1)

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../electrical- safety-standards-for-lvmvhv-part-1

Nov 7, 2012 ... Electrical safety standards for LV/MV/HV includes water safely clearance on electrical fires, minimum ... Search. EEP - Electrical Engineering Portal ... Cable Installation Depths; Minimum Approach Distance of Crane or Moving Part from Live Conductor .... He is member of Institution of Engineers (MIE), India.

Electrical Safety Standards for LV/MV/HV (Part-3)

https://feedproxy.google.com/.../ElectricalEngineeringPortal/.../electrical- safety-standards-for-lvmvhv-part-3

Nov 14, 2012 ... Clearance above ground at the lowest conductor ... He is member of Institution of Engineers (MIE), India. He has more than 13 years ...